Further sanitizes and protects the consumer, as no bacteria may exist in an ozonic environment.
ANALYSIS ANALYTICAL METHODRESULTSREPORTING LIMITNEVADA STATE LIMIT
Bicarbonate SM2320 B595.00N/A
Chloride EPA 300.03.42.00400 mg/L
Fluoride SM 4500-F C1.30.402 mg/L
Sulfate EPA 300.09.52.00500 mg/L
TDSSM2540 C97.015.01000 mg/L
CalciumEPA 200.77.00.50N/A
MagnesiumEPA 200.70.660.50150 mg/L
PotassiumEPA 200.7ND*2.00N/A
SodiumEPA 200.7270.500.85 mg/8oz serving;salt free
Total ColiformSM9223 BAbsent 1.1MPN/100mlN/A
E. ColiSM9223 BAbsent Absent
CarbonateSM2320 BND*5.00
Hydroxide SM2320 BND*5.00

NEL Laboratories is an independent laboratory which regularly analyzes and tests TAHOE SPRINGS water. They give us assurance that standards are met and the high quality of our WATER is maintained as well. 

DRINKING WATER ANALYSIS REPORT

TOHOE SPRINGS processes water from the Las Vegas City water supply and produces a purified drinking water (.05 ppm) by using the following steps:

null

WATER SOFTENER

To remove properties such as excessive minerals and particles which cause “hardness”;
null

ACTIVE CARBON FILTERIZATION

To remove chlorine and impurities;
null

REVERSE OSMOSIS

To remove salt from the softening process and all other particles and impurities from the city water supply;
null

ACTIVE CARBON

FILTERIZATION is once again utilized to ensure that no chlorine or other impurities remain;
null

MICROFILTER

further filters the water to ensure that no traces of residual carbon or other impurities remain;
null

ULTRAVIOLET LIGHT

To sanitize the water and ensure no bacteria exist amidst the water molecules;
null

OZONIZATION

further sanitizes and protects the consumer, as no bacteria may exist in an ozonic environment.
ANALYSISANALYTICAL METHODRESULTSDETECTION LIMITNEVADA STATE LIMIT
BicarbonateSM2320-B<25 mg/L25 mg/LN/A
ChlorideEPA 300.01.3  mg/L1.0 mg/L400 MG/L
FluorideSM 4500-F C<0.4 mg/L0.4 mg/L2 mg/L
SulfateEPA 300.00.7  mg/L0.1 mg/L500 mg/L
TDSSM2540 C25  mg/L25 mg/L1000 mg/L
CalciumEPA 200.74.1 mg/L0.1 mg/LN/A
MagnesiumEPA 200.70.34 mg/L0.25 mg/L150 mg/L
PotassiumEPA 200.71.4 mg/L1.0 mg/LN/A
SodiumEPA 200.72.4 mg/L0.25 MG/LN/A
Total ColiformSM9221-BAbsent1.1MPN/100MlAbsent

West Lakes Laboratory is an independent laboratory which regularly analyzes and tests TOHOE SPRINGS drinking water for bacteria or any impurity on a weekly basis. They give us assurance that standards are met and the high quality of our DRINKING WATER is maintained as well.

ALKALINE WATER ANALYSIS REPORT

AnalysesResultPQLQualUnitsMCLDFDate Analyzed
ALKALINITY, FULL – SDWA                                                  SM 2320 B                                                                            Analyst: JCT
Alkalinity, Bicarbonate (As CaCO3)32.05.00mg/L CaCO3111/3/2017 9:24:00 AM
Alkalinity, Carbonate (As CaCO3)ND5.00mg/L CaCO3111/3/2017 9:24:00 AM
Alkalinity, Hydroxide (As CaCO3)ND5.00mg/L CaCO3111/3/2017 9:24:00 AM
ANIONS-SDWA (CL, F, NO2, NO3, SO4)                           EPA 300.0                                                                               Analyst: K A
Chloride0.9510.100mg/L400111/1/2017 8:50:00 PM
FluorideND0.100mg/L4.00111/1/2017 8:50:00 PM
Sulfate0.7000.100mg/L500111/1/2017 8:50:00 PM
TOTAL DISSOLVED SOLIDS – CWA                                      SM 2540C                                                                              Analyst: JCT
Total Dissolved Solids40.05.00mg/L111/2/2017 8:45:00 AM
METALS-SDWA 200.7                                                              EPA 200.7                                                                               Analyst: JS
CalciumND1.00mg/L111/8/2017 2:20:46 PM
MagnesiumND1.00mg/L150111/8/2017 2:20:46 PM
Potassium10.81.00mg/L111/8/2017 2:20:46 PM
Sodium2.461.00mg/L111/8/2017 2:20:46 PM
COLIFORMS – MPN (DRINKING WATER)                          COLILERT-18                                                             Analyst: JCT
Coliform, TotalND1.0000CFU/100ml110/31/2017 4:30:00PM
Escherichia ColiND1.0000CFU/100ml110/31/2017 4:30:00PM